Boston Scientific Corporation cartesia tm directional dbs leads
(A) Boston Scientific <t>Cartesia™</t> and St. Jude Medical Directed 6172 <t>directional</t> leads and the CT artifacts seen at the level of the marker and segmented electrodes, (B) Distributions of the actual orientations calculated with DiODe for leads intended to face anterior (C) Distributions of deviation between the actual and intended orientations for both <t>DBS</t> systems as calculated by each user (K.H. and M.M.), (D) the agreement of actual orientations calculated by each user, K.H. and M.M., for the Boston Scientific (red points) and St. Jude (blue points) leads.
Cartesia Tm Directional Dbs Leads, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/cartesia tm directional dbs leads/product/Boston Scientific Corporation
Average 90 stars, based on 1 article reviews
cartesia tm directional dbs leads - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Boston Scientific Corporation 1-3-3-1 directional lead boston scientific vercise dbs system
(A) Line segments show within-participant changes in cognitive performance over time after DBS surgery, and bold lines show sample means. On tests of verbal fluency and memory, higher scores reflect improvement, while a lower score on response inhibition reflects an improved (i.e., faster) performance. p-values indicate significance of slopes over time. (B) Unity plots contrast cognitive performance with double-blind comparison of ring versus <t>directional</t> stimulation. p-values indicate significance of the binomial test in improvement on either stimulation setting.
1 3 3 1 Directional Lead Boston Scientific Vercise Dbs System, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/1-3-3-1 directional lead boston scientific vercise dbs system/product/Boston Scientific Corporation
Average 90 stars, based on 1 article reviews
1-3-3-1 directional lead boston scientific vercise dbs system - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Boston Scientific Corporation vercise pc ipg with directional dbs lead
Ongoing or upcoming interventional trials in dystonia
Vercise Pc Ipg With Directional Dbs Lead, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/vercise pc ipg with directional dbs lead/product/Boston Scientific Corporation
Average 90 stars, based on 1 article reviews
vercise pc ipg with directional dbs lead - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Boston Scientific Corporation segmented electrode vercise dbs directional lead model
Ongoing or upcoming interventional trials in dystonia
Segmented Electrode Vercise Dbs Directional Lead Model, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/segmented electrode vercise dbs directional lead model/product/Boston Scientific Corporation
Average 90 stars, based on 1 article reviews
segmented electrode vercise dbs directional lead model - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

Image Search Results


(A) Boston Scientific Cartesia™ and St. Jude Medical Directed 6172 directional leads and the CT artifacts seen at the level of the marker and segmented electrodes, (B) Distributions of the actual orientations calculated with DiODe for leads intended to face anterior (C) Distributions of deviation between the actual and intended orientations for both DBS systems as calculated by each user (K.H. and M.M.), (D) the agreement of actual orientations calculated by each user, K.H. and M.M., for the Boston Scientific (red points) and St. Jude (blue points) leads.

Journal: Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference

Article Title: Analysis of the intended and actual orientations of directional deep brain stimulation leads across deep brain stimulation systems

doi: 10.1109/EMBC48229.2022.9871608

Figure Lengend Snippet: (A) Boston Scientific Cartesia™ and St. Jude Medical Directed 6172 directional leads and the CT artifacts seen at the level of the marker and segmented electrodes, (B) Distributions of the actual orientations calculated with DiODe for leads intended to face anterior (C) Distributions of deviation between the actual and intended orientations for both DBS systems as calculated by each user (K.H. and M.M.), (D) the agreement of actual orientations calculated by each user, K.H. and M.M., for the Boston Scientific (red points) and St. Jude (blue points) leads.

Article Snippet: When localizing the postoperative leads with DiODe, large deviations of up to 90° have been reported between the intended and actual orientations in patients implanted with Cartesia TM directional DBS leads (Boston Scientific, USA) [ 8 ].

Techniques: Marker

(A) Line segments show within-participant changes in cognitive performance over time after DBS surgery, and bold lines show sample means. On tests of verbal fluency and memory, higher scores reflect improvement, while a lower score on response inhibition reflects an improved (i.e., faster) performance. p-values indicate significance of slopes over time. (B) Unity plots contrast cognitive performance with double-blind comparison of ring versus directional stimulation. p-values indicate significance of the binomial test in improvement on either stimulation setting.

Journal: medRxiv

Article Title: Differential cognitive effects of unilateral left and right subthalamic nucleus deep brain stimulation for Parkinson disease

doi: 10.1101/2023.02.27.23286478

Figure Lengend Snippet: (A) Line segments show within-participant changes in cognitive performance over time after DBS surgery, and bold lines show sample means. On tests of verbal fluency and memory, higher scores reflect improvement, while a lower score on response inhibition reflects an improved (i.e., faster) performance. p-values indicate significance of slopes over time. (B) Unity plots contrast cognitive performance with double-blind comparison of ring versus directional stimulation. p-values indicate significance of the binomial test in improvement on either stimulation setting.

Article Snippet: The same neurosurgeons (BG, JNB) implanted a 1-3-3-1 directional lead (Boston Scientific Vercise DBS system, Natick MA, USA, FDA IDE# G170063) at the STN target under local anesthesia with the patient fully awake.

Techniques: Inhibition, Comparison

Binomial tests of cognitive performance by stimulation mode

Journal: medRxiv

Article Title: Differential cognitive effects of unilateral left and right subthalamic nucleus deep brain stimulation for Parkinson disease

doi: 10.1101/2023.02.27.23286478

Figure Lengend Snippet: Binomial tests of cognitive performance by stimulation mode

Article Snippet: The same neurosurgeons (BG, JNB) implanted a 1-3-3-1 directional lead (Boston Scientific Vercise DBS system, Natick MA, USA, FDA IDE# G170063) at the STN target under local anesthesia with the patient fully awake.

Techniques: Inhibition

Ongoing or upcoming interventional trials in dystonia

Journal: Neurotherapeutics

Article Title: Treatment of Dystonia: Medications, Neurotoxins, Neuromodulation, and Rehabilitation

doi: 10.1007/s13311-020-00944-0

Figure Lengend Snippet: Ongoing or upcoming interventional trials in dystonia

Article Snippet: Unlocking Dystonia from Parkinson’s Disease with Directional DBS Technology , Boston Scientific Vercise PC IPG with directional DBS lead , University of Alabama at Birmingham, Birmingham, Alabama, USA , {"type":"clinical-trial","attrs":{"text":"NCT03409120","term_id":"NCT03409120"}} NCT03409120.

Techniques: Activity Assay, Injection, Isolation, Western Blot